PENGARUH JARAK KONDUKTOR BERKAS TERHADAP RUGI DAYA PADA SUTET 275 KV KILIRAN JAO - PAYAKUMBUH
Sari
The goal of the research on the effect of beam conductor distance on power losses on the 275 kV Kiliran Jao to Payakumbuh SUTET's 126.4 km long line is to determine the inductive reactance value based on power losses on inductive resistance and reactance rather than distance. The inductive reactance value is not based on the beam conductor distance of XL= 0,3111 km with a total inductive reactance value of Xtotal= 39,323Ω/km , according to the findings of the calculations performed. Based on the beam conductor distances of XR=0.238 km on distance (s)=0.06m, XL=0,3111 Ω/km on phase distance(s) = 0.26m (distance at system),and XL=0,2931 Ω/km on distance (s)=0.46m, the inductance reactance value is calculated. In the meantime, inductive reactance has a value of 34,8 MW in power loss, resistance has a value of 122 MW in power losses and capasitive reactance has a value 31,5MW in power loss. According to the calculation's findings, large currents and resistance can affect the amount of power lost in resistance, whereas the radius of the conductor wire, the spacing between conductors, and the number of layers of conductor wire can affect the amount of power lost in inductive reactance.
Keywords : Conducting wire, Inductive reactance value, Power losses
Teks Lengkap:
PDFReferensi
Anggoro, B. A., Utomo, S. B., & Widihastuti, I. (2020). Analisa Rugi-Rugi Daya Dan Jatuh Tegangan Pada Saluran Transmisi 150 kV GI Pati Bay GI Jekulo Menggunakan ETAP 12.6.0. Elektrika, 12(2), 80.
Cahyadi, C. I., Atmia, K., & Fitriani, A. (2022). Analisis Pengaruh Rugi-Rugi Daya Pada Jaringan Transmisi 150 kV Menggunakan. Jambura Journal of Electrical and Electronics Engineering, 4, 8–12.
Chairani, D. (2022). Analisis Pengaruh Korona Terhadap Rugi-Rugi Daya pada Saluran Transmisi. Jurnal Pendidikan Sains Dan Komputer, 2(2), 2809–476.
Corbellini, U., & Pelacchi, P. (1996). Corona losses in HVdc bipolar lines. IEEE Transactions on Power Delivery, 11(3), 1475–1481. https://doi.org/10.1109/61.517506
Dalila, S. L. (2022). Analisa Rugi - Rugi Daya Pada Saluran Transmisi Tegangan Tinggi 150 kV Dari Gardu Induk PLN Bireun Ke Gardu Induk PLN Banda Aceh. 7(1), 23.
Dani, A. (2021). ANALISIS RUGI-RUGI DAYA PADA SALURAN TRANSMISI 150 KV PADA GARDU INDUK KIM. Jurnal Indonesia Sosial Teknologi, 2(11), 1892–1901.
Dewi, A. (2020). Studi Analisa Pengaruh Temperatur Dan Tekanan Udara Terhadap Rugi Daya Korona SUTT 150 kV. Jurnal Teknik Elektro ITP, 9(1), 47–53. https://doi.org/10.21063/jte.2020.3133909
ELGANAI, A. A. M. (2019). The Corona Effect on High Voltage Transmission Lines. IJSETR,International Journal of Scientific Engineering and Technology Research, 08(December 2019), 29–31.
Lu, F., You, S., Liu, Y., & Zhu, L. (2011). Harmonic wave analysis of conductor corona current based on wide frequency band measurement. 2011 International Conference on Electrical and Control Engineering, ICECE 2011 - Proceedings, 121058, 2258–2261. https://doi.org/10.1109/ICECENG.2011.6057380
Masarrang, R., Patras, L. S., Tumaliang, H., & Transmisi, A. P. S. (2019). Efek Korona pada Saluran Transmisi Gardu Induk Tello Sulawesi Selatan. Jurnal Teknik Elektro Dan Komputer, 8(2), 67–74.
Nababan, A. P. (2014). GANGGUAN BERISIK DAN INTERFERENSI RADIO PADA SALURAN TRANSMISI UDARA TEGANGAN EKSTRA TINGGI 275 kV.
Nawir, H., Suharti, F., & Kamil, I. (2019). Simulasi Pengaruh Variasi Konduktor Berkas Terhadap Gangguan Berisik Dan Radio Interferensi Pada Saluran Udara Tegangan Ekstra Tinggi 275kV. 17(2), 139–149.
Nurdin, A., & Azis, A. (2018). Pengaruh Jarak Antar Sub Konduktor Berkas Reaktansi Induktif Saluran Terhadap Transmisi 150 Kv Dari Gardu Induk Keramasan Ke Gardu Induk Mariana. Jurnal Ampere, 3(2), 145. https://doi.org/10.31851/ampere.v3i2.2395
Rifal, R., Utomo, S. B., & Haddin, M. (2020). Analisis Perhitungan Rugi-Rugi Daya pada Saluran Transmisi Tegangan Tinggi 150 kV Gardu Induk Tambak Lorok – Bawen dengan menggunakan Etap 12.6.0. Prosiding Konferensi Ilmiah Mahasiswa Unissula (KIMU) Klaster Engineering, 0(0), 234–243. http://lppm-unissula.com/jurnal.unissula.ac.id/index.php/kimueng/article/view/8592
Tamam, I. B., Koerniawan, T., & Ichsan, M. N. (2017). ANALISA PEMBANGUNAN SALURAN TRANSMISI 275 kV ANTARA GI KILIRANJAO DAN GI PAYAKUMBUH. Energi & Kelistrikan, 9(1), 93–99.
Wardana, A. (2022). Kajian Rugi-Rugi Daya Dengan Menggunakan Software Powerworld Versi 12 Pada Saluran Transmisi Tegangan Tinggi 150 Kv Pada Gardu Induk Payageli-Gardu Induk Glugur. Jurnal Ilmiah Mahasiswa Teknik [JIMT], 2(2), 1–8.
Zaki, A., & Dewi, A. Y. (2022). ANALISIS PENGARUH KORONA TERHADAP AUDIBLE NOISE PADA SUTET 275 KV KILIRAN JAO-PAYAKUMBUH. 357–365.
DOI: https://doi.org/10.33559/eoj.v6i2.2078
Refbacks
- Saat ini tidak ada refbacks.
Negara Pengunjung

Ciptaan disebarluaskan di bawah Lisensi Creative Commons Atribusi 4.0 Internasional.