Indonesia continues to follow the development of building standards in the world which are dynamically changing for the better and safer, both in loading regulations, planning for concrete structures, steel structures, and planning for earthquake resistance. The latest planning standard methods reviewed in this study are SNI-03-1726-2019, SNI-03-2847-2019 and RSNI-03-1727-2020 replacing SNI-03-1726-2012, SNI-03-1727-2013, and SNI-03-2847-2013. The basic difference in SNI-03-1726:2012 compared to SNI-03-1726:2019 is in the coefficients of Fa and Fv, namely the coefficient of soil sites for a long earthquake period of 1 second and in SNI-03-2847:2019 which refers to ACI 318M-14 Building Code Requirements for Structural Concrete. The results of this study found that this change in the modeling of the West Pasaman Regional General Hospital met the requirements for the SNI-03-1726-2019 earthquake design and the SNI-03-2847-2019 reinforced concrete design.

Teks Lengkap:

PDF PDF

Referensi


Arifin, Z., Suryadi., Sebayang, S. (2015). Analisis Struktur Gedung POP Hotel Terhadap Beban Gempa Dengan Metode Pushover Analisis. JRSDD edisi September Vol 3 No 3 Hal :427-440 (ISSN: 2003-0011).

Bambang.,Afif, M. (2017). Kriteria Dasar Struktur Bangunan Tahan Gempa. Universitas 17 Agustus 1945 Semarang.

Fauziah, R. (2015). Studi Perbandingan Pembebanan gempa Statik Ekuivalent dan Dinamik Time History pada Gedung Bertingkat Yogyakarta. Jurnal Ilmiah Semesta Teknika Vol. 18, No.2 Hal 190-199.

Febrian, D.B., Budi, A.S., Sambowo.K.A. (2014). Evaluasi Kinerja Gaya Gempa Pada Gedung Bertingkat Dengan Analisis Respon Spektrum Berdasarkan Base Shear, Dispalacement, Dan Drift Menggunakan Software Etabs (Studi Kasus : Hotel Di Daerah Karanganyar). e-Jurnal Matriks Teknik Sipil Vol.1 No 2.

Hermanto, A., Widyarti, M., Fauzan, M. (2012). Analisis Struktur Bangunan Apartemen Grand Emerald Kelapa Gading Jakarta Utara Menggunakan Peta Gempa 2002 Dengan Anlisis Statik Equivalent. Institut Teknologi Pertanian Bogor.

Saputra, A., Firmanto, A. (2017). Analisis Struktur Rumah Sakit Pemata Cirebon. UNSWAGATI Cirebon. ISSN 2085:8744.

SNI 03-1726-2019 tentang tata cara perencanaan ketahanan gempa untuk struktural bangunan gedung dan non gedung. Jakarta.

RSNI 03-1727-2020. tentang beban minimum untuk perancangan bangunan gedung dan struktur lain. Jakarta.

SNI 03-2847-2019.tentang persyaran beton struktural untuk bangunan gedung. Jakarta.